Products & specifications

Standard constructions listed below. Where a project specifies something slightly different — a particular sheath compound, a reduced neutral, a specific drum length — send the requirement and we will confirm whether it can be met before quoting.

Range coverage

What we can quote

The three lines below are the ones we are asked for most. This is the wider set behind them — the same enquiry form works for any item on the list.

LV power cable, 0.6/1 kV — XLPE/PVC, SWA / STA / unarmoured LSZH power cable — BS 6724 · BS 7211 PVC power cable — BS 6346, 70 °C Building wire — BV · BVR, 450/750 V Flexible cords — H05V-U · H07V-K · H05VV-F · H07RN-F Control cable — screened & unscreened, 0.6/1 kV Fire-resistant cable — IEC 60331 / BS 6387 constructions Aluminium conductor — YJLV · YJLV22 Rubber-insulated & welding cable — YC · YH Instrumentation & signal cable — screened, twisted pair Overhead & service-drop cable — ABC Bare copper conductor & earthing wire

Anything not listed — send the BOQ line or the drawing. Most omissions here are a lead-time question rather than a capability one. Send the item →

Find it your way

The range, from four directions

Engineers arrive with a standard number. Buyers arrive with an application. Consultants arrive with a performance clause. Pick whichever door you already have the key to.

Only the first four standard pages are built so far — the rest of the map is being filled in. If the item you need isn't a link yet, it is very likely still quotable: send the line and find out. Send the item →

01 — Power

LV power cables, 0.6/1 kV

Armoured and unarmoured low-voltage cables for fixed distribution, sub-mains and auxiliary circuits. The armoured constructions are the workhorse of Gulf building projects.

TECHNICAL DATA — LV POWER CABLES
PropertySpecification
StandardsBS 5467 XLPE/SWA/PVC  ·  BS 6724 XLPE/SWA/LSZH  ·  IEC 60502-1  ·  BS 7889 unarmoured  ·  BS 6346 PVC/SWA/PVC
Voltage rating0.6/1 kV (600/1000 V)
ConductorClass 2 stranded copper to BS EN 60228 / IEC 60228. Class 1 solid available on request.
InsulationXLPE — maximum conductor operating temperature 90°C
ArmourSteel wire armour (SWA) — the Gulf default for multicore LV. Aluminium wire armour (AWA) for single-core AC. Steel tape (STA) available on request.
Bedding & sheathPVC (BS 5467) or LSZH compound (BS 6724)
Core configuration1 to 5 cores; equal section or reduced neutral. Control constructions up to 48 cores on request.
Size range1.5 – 300 mm²
Sheath colourBlack standard; other colours on request
EnvironmentalUV-resistant outer sheath available — recommended for outdoor and Gulf installations
PackingWooden drums, IPPC-fumigated; drum marking to buyer's instruction
BS 5467

Cu / XLPE / SWA / PVC

The standard armoured LV power cable for fixed industrial wiring and mains distribution. PVC bedding and outer sheath.

N2XRY0.6/1 kV
BS 6724

Cu / XLPE / SWA / LSZH

Identical construction to BS 5467, but with a low-smoke zero-halogen bedding and sheath. Specified where fire emissions matter.

N2XRHLSZH
BS 7889

Cu / XLPE / PVC — unarmoured

Unarmoured XLPE/PVC for installation in ducts, trunking or on tray where mechanical protection isn't required.

UnarmouredIEC 60502-1
02 — Wires

Building wires, 450/750 V

Single-core PVC-insulated wires for final circuits in residential, commercial and light industrial work — usually the highest-volume line item on a project.

TECHNICAL DATA — BUILDING WIRES
PropertySpecification
StandardsIEC 60227  ·  BS 6004
Voltage rating450/750 V
TypesBV single-core PVC insulated  ·  BVR flexible stranded conductor
ConductorClass 1 solid or Class 2 stranded annealed copper, to IEC 60228
InsulationPVC — maximum conductor operating temperature 70°C
Size range1.5 – 240 mm²
Core coloursRed, yellow, blue, green/yellow, black, brown, grey
PackingCoils (100 m standard) or drums, to buyer's instruction
03 — LSZH

LSZH & fire-performance cables

Low-smoke zero-halogen constructions are a firm requirement in Gulf high-rise and public building specifications. Unlike PVC, they do not emit dense black smoke or corrosive halogen gases when burnt.

PropertySpecification
LSZH armouredBS 6724 — Cu / XLPE / SWA / LSZH, 0.6/1 kV
LSZH unarmouredBS 7211
Halogen acid gasIEC 60754-1 / IEC 60754-2
Smoke densityIEC 61034 — minimum 60% light transmittance under the 3 m cube test
Flame propagationIEC 60332-1-2 single cable. IEC 60332-3-22 / -23 / -24 bunched, Cat A / B / C.
Fire resistanceBS 6387 (C / W / Z) and IEC 60331 constructions — available to project specification
WHERE IT GOES

Typical LSZH applications

  • High-rise residential and commercial towers
  • Public buildings, hospitals, schools, retail centres
  • Tunnels, basements and enclosed escape routes
  • Metro, airport and transport infrastructure
  • Data and instrumentation rooms with sensitive equipment
  • Life-safety circuits where supply must survive a fire
i
Fire-resistance reporting Where a project requires a third-party fire-resistance test report — BS 6387 CWZ, BS EN 50200, BASEC or LPCB — tell us at tender stage. Some of these are project-driven and best planned before the order rather than after it.
Reference

Standards cross-reference

The table below maps the British standards Gulf specifications most often cite onto their construction and international equivalent. It is here so you can sanity-check a bill of quantities against what we supply.

British standard Construction International equivalent Typical application
BS 5467Cu / XLPE / SWA / PVCIEC 60502-1 (N2XRY)LV power distribution, sub-mains
BS 6724Cu / XLPE / SWA / LSZHIEC 60502-1 (N2XRH)LSZH armoured, public buildings
BS 7889Cu / XLPE / PVC, unarmouredIEC 60502-1Ducts, trunking, cable tray
BS 7211Cu / XLPE / LSZH, unarmoured—LSZH where armour isn't required
BS 6346Cu / PVC / SWA / PVC—PVC-insulated, 70°C, cost-driven
BS 6004450/750 V PVC single-coreIEC 60227Building wires, final circuits
BS 6387Fire-resistance test — C / W / ZIEC 60331High-rise, life-safety circuits *
BS 7846Fire-resistant + armoured + LSHF—Fire pumps, smoke extraction *

* Fire-resistance constructions are supplied to project specification. Third-party fire-test reports are arranged case by case — raise it at tender stage and we will confirm what is achievable and in what timeframe.

Practical note

How a cable specification reads

If you are assembling an enquiry, this is the order that leaves least room for misunderstanding. Send it in this form and you will get a quotation you can compare line for line against anyone else's.

4 C × 300 mm²
XLPE / SWA / PVC
600/1000 V
Class 2 stranded copper
to BS 5467, IEC 60502-1

  • Core count & size — e.g. 4 C × 300 mm²
  • Insulation / armour / sheath — in that order: XLPE / SWA / PVC
  • Voltage — 600/1000 V is the same as 0.6/1 kV
  • Conductor class — Class 2 stranded is the fixed-installation standard
  • Standard — the BS number, plus the IEC equivalent if the project cites both

Three things worth confirming early

01 · ARMOUR TYPE

SWA (steel wire) and STA (steel tape) are not interchangeable and do not cost the same. Gulf LV projects usually mean SWA — confirm it rather than assume it.

02 · NEUTRAL SIZE

Reduced neutral saves money; full-size neutral is often required where single-phase loads are unbalanced. Tell us which the project calls for.

03 · AMBIENT TEMPERATURE

Catalogue current ratings assume temperate conditions. At 45–50°C ambient the derating factor matters — ask for corrected figures for your sizes.